3. SELECTING THE INSTALLATION SITE

3. SELECTING THE INSTALLATION SITE

3-1. Outdoor Unit

AVOID:

3-1. Outdoor Unit heat sources, exhaust fans, etc. (Fig. 1-3)

Installation space damp, humid or uneven locations

DO:

Installation requirements choose a place as cool as possible.

Manual background choose a place that is well ventilated and outside air temperature does not exceed maximum 115°F constantly.

Hot air

Out- door unit

1. Specifications

Exhaust fan

Heat source

Manual background allow enough room around the unit for air intake/ exhaust and possible maintenance. (Fig. 1-4)

Manual background use lug bolts or equal to bolt down unit, reducing vibration and noise.

Manual background if cooling operation is to be used when the outdoor air temperature is 23°F or below, install a duct on

the outdoor unit.

Installation space

Distance between obstructions and the unit air inlet and outlet must be as shown below.

*3

Inlet side C

More than 1/2"

More than 1/2"

*2 Manual backgroundManual background *4

Outlet side More than 3.3 ft.

*1

Fig. 1-4

Fig. 1-3

1

(Obstruction above unit)

Air direction chamber

(field supply)

 

B

 

A

*1

Inlet side

More than 8"

 

(Obstruction on

 

inlet side)

(Ground)

Fig. 1-5

CAUTION

Manual background Concerning inlet-side distance “C” (Fig. 1-4)

The minimum for distance “C” is 6" if there are no obstructions on the outlet side (wall *1 side) and *2 or *4 is not present. In all other cases, the minimum for distance “C” is 8".

Manual background If the unit is installed with the outlet side facing wall *1, then there must be no obstructions on 2 of the remaining 3 sides: *2, *3, *4.

Manual background If wall *1 is on the outlet side (Fig. 1-4), or if obstructions are present on all 3 sides *2, *3, and *4 (Fig. 1-4), then the minimum distance for “A” and “B” is 80" (Fig. 1-5). Even if there is no wall on the outlet side, a minimum of 3.3 ft. is required.

Installation requirements

Manual background provide a solid base (concrete block, 4"×16" beams or equal), a minimum of 6" above ground level to reduce humidity and protect the unit against possible water damage and decreased service life. (Fig. 1-6)

Manual background use lug bolts or equal to bolt down unit, reducing vibration and noise.

Anchor bolts (4 pieces)

Fig. 1-6

1-65