Operation and Maintenance
5-4 9123-A2-GB20-10
July 2000
LED Descriptions

The following table identifies the alarms that cause the Alarm LED to light. See

Table 5-2 and Table 5-3 for network and user data port interface LED information.

Table 5-1. General Status LEDs (1 of 2)

Label Indication Color What It Means

OK Power and
Operational
Status
Green ON FrameSaver unit has power and it is
operational.
OFF– FrameSaver unit is in a power-on
self-test, or there is a failure.
ALM Operational
Alarm (Fail) Red ON FrameSaver unit has just been reset,
or an error or fault has been detected.
Error/fault/alarm conditions:
HAlarm Indication Signal (AIS)
HCTS Down
HDLCI Down
HDTR Down
HExceeded Error Rate (EER)
HLMI Down
HLoss of Signal (LOS)
HOut of Frame (OOF)
HPrimary Clock Failed
HSelf-Test Failed
HSLV Timeout
HTwo Level-1 Users Accessing
Device
HYellow Alarm Signal
OFF– No failures have been detected.
These alarms appear on the System and
Test Status screen. See
Health and Status
Messages
for additional information.
TST Test Mode Yellow ON Loopback or test pattern is in progress,
initiated locally, remotely, or from the
network.
OFF– No tests are active.