Operation and Maintenance

DLCIs without an asterisk have not been configured in the unit. These DLCIs pass through the unit transparently, without being monitored and with no demultiplexing/multiplexing of management diagnostics or user data being performed. Only DLCIs on the Net1-FR1 and Port-1 frame relay links appear on this screen; nonconfigured DLCIs on other links are discarded.

Table 5-9. Network LMI-Reported DLCIs Status

Field

Status

What It Indicates

 

 

 

DLCI

16 through 1007

Identifies the Local Management

 

 

Interface-reported DLCI numbers

 

 

assigned to the selected interface ± the

 

 

identifying number assigned to the path

 

 

between two frame relay FrameSaver

 

 

units' ports.

 

 

DLCI statuses are listed in ascending

 

 

order (i.e., lowest number first).

 

 

 

Status

 

LMI-reported status of the DLCI:

 

Active

H Whether the DLCI is active (capable

 

 

of carrying data) in the frame relay

 

 

network,

 

 

 

 

Inactive

H Whether it is inactive in the frame

 

 

relay network,

 

Deleted 1

 

 

H Whether it has been deleted by the

 

 

frame relay network, or

 

New 1

 

 

H Whether it has been created by the

 

 

frame relay network.

 

 

 

CIR (bps)

0±1536000

Displays the committed information rate

 

 

reported by the Stratacom switch. CIR

 

 

information only appears in this column

 

 

when LMI Protocol is set to Standard.

 

 

If blank, the switch does not support this

 

 

feature.

 

 

 

1Appears for 10 seconds only, before the network changes Deleted to Inactive and New to Active.

9123-A2-GB20-10

July 2000

5-19

Page 127
Image 127
Paradyne 9123 manual Network LMI-Reported DLCIs Status Field What It Indicates