Troubleshooting

Repeater Loopback

The local Repeater Loopback (RLB) loops data received from the user data port after the signal has passed through the framing circuitry. Use the RLB to ensure that all of the data is correct up to the point where it is sent over the interface.

This helps to indicate that the FrameSaver unit is operational.

Main Menu Test Network Physical Tests

An attached device or test equipment should generate and monitor data to be looped back.

Other

T1

Interface

Framer

RLB

AIS

The T1

Interface

 

 

97-15338

The FrameSaver unit will not respond to any messages from the network during this test.

CAUTION:

This test may affect the operation of the frame relay PVCs assigned to the selected port. While in loopback, the frame relay link will be down so any IP data being sent while this test is active will be disrupted.

An RLB cannot be started when one of the following tests is active:

HPayload Loopback, Send Remote Line Loopback, or an active Monitor Pattern on this network interface.

9123-A2-GB20-10

July 2000

6-23

Page 175
Image 175
Paradyne 9123 manual Repeater Loopback