Configuration

Table 3-10. Management PVC Options (3 of 3)

Primary DLCI

Possible Settings: 16 ± 1007

Default Setting: Initially blank; no default.

Specifies the DLCI number used for the management PVC after the frame relay interface is selected.

The DLCI must be defined for the link (i.e., has a DLCI record), and it must not be part of a PVC connection or already assigned as a management PVC. For multiplexed DLCIs, at least one EDLCI must be unconfigured for the DLCI.

NOTES: ± DLCI cannot be entered if the Link field is blank.

± Clearing the Link also clears the DLCI.

16 ± 1007 ± Specifies the DLCI number (inclusive).

Primary EDLCI

Possible Settings: 0 ± 62

Default Setting: Initially blank; no default.

Specifies the EDLCI number used for a management PVC when a multiplexed DLCI is selected. EDLCIs identify individual connections within multiplexed DLCIs that are unique to those DLCIs.

Use a unique EDLCI to identify an individual connection within a multiplexed DLCI. Use 0 to identify the primary EDLCI. Use 1 ± 62 to identify secondary EDLCIs. Use the primary EDLCI for customer data, which has a higher utilization rate than management data, with slightly less line overhead.

Display Conditions ± This option does not appear if the DLCI field does not reference a multiplexed DLCI.

NOTE: Clearing the DLCI or changing it to a standard DLCI suppresses EDLCI field.

0 ± 62 ± Specifies the EDLCI number (inclusive).

Primary Link RIP

Possible Settings: None, Proprietary, Standard_out

Default Setting:

For multiplexed DLCIs: Proprietary

For nonmultiplexed DLCIs: Standard_out

Specifies which Routing Information Protocol (RIP) is used to enable routing of management between FrameSaver units and attached equipment.

None ± Does not use a routing protocol.

Proprietary ± Uses a proprietary variant of RIP version 1 to communicate routing information between FrameSaver units. A FrameSaver unit must be on the other end of the link. This is the factory default for management PVCs configured on multiplexed DLCIs (see Table 3-7,DLCI Record Options).

Standard_out ± The device will send standard RIP messages to communicate routing information only about FrameSaver FLEX and SLV units in the network. This is the factory default for management PVCs configured on standard DLCIs.

NOTE: The router must be configured to receive RIP on the port connected to the FrameSaver unit for the management interface (e.g., Cisco: config-t, router RIP, int serialx, IP RIP Receive version 1, ctl-zWR). See Setting Up So the Router Can Receive RIP.

3-48

July 2000

9123-A2-GB20-10