Table 3-9. Node IP Options (2 of 3)
TS Access Management Link
Available Settings: None, PVCname
Default Setting: None
Specifies a troubleshooting management link for the special needs of network service providers.
Display Conditions ± This option only appears when Service Type on the Easy Install screen is set to Frame Relay.
If the setting is changed from the management PVC name to None, the Delete the Management PVC PVCname and the associated DLCI Record? prompt appears. If you select:
HNo ± The link designation is removed and the option is set to None.
HYes ± The link designation is removed and the option is set to None, and the link and its DLCI will be deleted.
None ± Disables or does not specify a TS Access Management Link.
PVCname ± Specifies the name of the TS Management PVC.
Display Conditions ± This selection only appears when a dedicated management PVC has been defined on the network frame relay link as a DLCI with DLCI Type set to Standard.
TS Management Link Access Level
Available Settings:
Default Setting:
Specifies the highest access level allowed when accessing the unit via a Telnet or FTP session when the service provider is using the TS Access Management Link.
Display Conditions ± This option only appears when:
HService Type on the Easy Install screen is set to Frame Relay.
HTS Access Management Link is set to None.
NOTES: Telnet and FTP sessions on this link are not affected by the access level set by the Session Access Level, Login Required, or FTP Login Required option settings (see Table
Telnet and FTP sessions on this link are affected by the Telnet Session, Inactivity Timeout, Disconnect Time and FTP Session option settings.