Operation and Maintenance

Clearing Performance Statistics

Performance statistics counters can be reset to the baseline when using a directly-connected asynchronous terminal and your security Access Level is Level-1. This feature is useful when troubleshooting problems.

Statistic counters are not actually cleared using this feature. True statistic counts are always maintained so SLAs can be verified, and they can be viewed from an SNMP NMS. However, since statistics can be cleared locally, the statistics viewed via the menu-driven user interface may be different from those viewed from the NMS.

"Procedure

To clear all statistics:

Performance Statistics Clear All Statistics

"Procedure

To clear specific sets of statistics:

HUse the C lrSLV&DLCIStats function key to reset the SLV and DLCI performance statistic counters for the currently displayed DLCI from one of the following screens:

Performance Statistics Service Level Verification

Performance Statistics DLCI

HUse the C lrLinkStats function key to reset the frame relay link performance statistics.

Performance Statistics Frame Relay

HUse the ClrNearStats or ClrFarStats function key to reset all near-end or all far-end Extended SuperFrame (ESF) line performance statistics.

Performance Statistics ESF Line

9123-A2-GB20-10

July 2000

5-27

Page 135
Image 135
Paradyne 9123 manual Clearing Performance Statistics, Performance Statistics → Clear All Statistics