Troubleshooting

Table 6-2. Device Problems (2 of 2)

Symptom

Possible Cause

Solutions

 

 

 

Cannot access the

Login or password is

H Reset the unit (see

unit or the

incorrect, COM port is

Restoring Communication

menu-driven user

misconfigured, or the unit is

with a Misconfigured Unit.)

interface.

otherwise configured so it

H Contact your service

 

prevents access.

 

representative.

 

 

 

 

 

Failure xxxxxxxx

The unit has detected an

H Record the 8-digit code from

appears at the top of

internal software failure.

the System and Test Status

the System and Test

 

screen.

Status screen, at

 

H Reset the unit and try again.

Self-Test Results.

 

 

 

 

 

H Contact your service

 

 

representative and provide the

 

 

8-digit failure code.

 

 

 

An LED appears

LED is burned out.

Run the Lamp Test. If the LED in

dysfunctional.

 

question does not flash with the

 

 

other LEDs, then contact your

 

 

service representative.

 

 

 

Not receiving data.

Network cable loose or

H Reconnect or repair the cable.

 

broken.

H Call the network service

 

 

 

 

provider.

 

 

 

Receiving data errors

Frame Relay Discovery is

Change the DLCI Type for each

on a multiplexed DLCI,

being used for automatic

network DLCI from Multiplexed to

but frame relay is

DLCI and PVC

Standard, turning off

okay.

configuration.

multiplexing.

 

The equipment at the other

 

 

end is not frame relay

 

 

RFC 1490-compliant.

 

 

 

 

6-12

July 2000

9123-A2-GB20-10

Page 164
Image 164
Paradyne 9123 manual Device Problems 2 Symptom Possible Cause Solutions, With a Misconfigured Unit