Configuration

When a Frame Relay Discovery Mode is changed and saved, the Saving will

cause Auto-Configuration to update and Restart. Are you sure? prompt appears. No is the default for this prompt.

HIf Yes (y) is entered, the Delete All DLCIs and PVC Connections? prompt appears. No is the default for this prompt.

ÐIf Y es is entered, all multiplexed DLCIs and PVC Connections are deleted, except for Management PVCs with the user data port as the primary destination and the Management PVC that is designated as TS Management Link.

ÐIf N o is entered, previously discovered and auto-configured option settings will not be removed, but configuration updates due to LMI response messages are performed according to the just saved mode setting.

HIf No (n) is entered, or if you exit the screen without responding to the prompt, no Auto-Configuration updates are performed and updates due to LMI response messages are performed according to the previously saved setting.

Automatically Removing a Circuit

Using the automatic circuit removal feature, which comes enabled, network DLCIs and PVCs can be automatically removed from the unit's configuration when the the network service provider no longer supports them. Automatic deletion is based upon information from a LMI full status response on an active frame relay link.

When this feature is set to:

HEnable ± The following will be automatically removed from the unit's configuration:

ÐUnsupported network DLCIs and PVC connections that include multiplexed network DLCIs.

ÐUnsupported standard network DLCIs that are not configured as the primary destination in a management PVC.

ÐNon-management PVCs in which unsupported standard network DLCIs are included.

ÐDLCIs not included in three consecutive LMI full status response messages.

ÐLMI status responses that indicate a Deleted status for the DLCI.

All configured options relating to the deleted circuits are also deleted and they revert to their default settings.

A DLCI will not be deleted if the physical interface or frame relay link is down, or if the DLCI is used for the TS Management Link.

HDisable ± Unused network DLCIs, PVC connections, and management PVCs must be manually removed.

3-14

July 2000

9123-A2-GB20-10

Page 46
Image 46
Paradyne 9123 manual Automatically Removing a Circuit