Chapter 6: Further Chart Operations

6-5

 

 

Setting Alarms and Timers

To set up an alarm or timer:

1. Press the ALARMS key. The Alarms Set Up menu is displayed, showing

ALARMS

the current settings (see Figure 6-2).

2.Use the trackpad to move the selection bar up or down the options. As each line is highlighted, the soft key labels are updated to show the current set- tings and controls.

ALARMS SET UP

 

 

ARRIVAL ALARM

0.01nm

OFF TRACK ALARM

ON

ANCHOR ALARM

OFF

COUNTDOWN TIMER

00:33:00

ALARM CLOCK

OFF

 

 

SELECT ARRIVAL

ALARM RADIUS

D4265-2

Figure 6-2: Alarms Set Up List

3.Use the up or down soft keys to change the alarm setting. For example, for the arrival alarm you can adjust the radius from the waypoint at which the arrival alarm will be triggered.

The alarm distances can be set in the range 0.01 to 9.99 nm, in steps of 0.01nm. The timer is set in hours, minutes and seconds, and the alarm clock in hours and minutes.

ALARM

4. If required, press the ALARM OFF ON soft key to toggle the alarm on or off.

OFF

ON

If you turn an alarm off, its value is retained and will be used when you turn

 

 

 

 

the alarm on again.

Note: You can turn all the alarms and timers on and off, except for the Arrival Alarm which is always on.

5. Press ENTER to save the changes and clear the list.