Chapter 7: Setting Up the System Defaults

7-13

 

 

To change the range scale, highlight the required range and use the soft keys to change the value. Start at the top of the list and work down, since each value must be greater than the value for the previous range in the list. The following scale increments are available:

Table 7-4:

Radar Range Scale Increments

 

 

Range Scales (nm)

Scale Increments (nm)

 

 

 

0.125 to 0.5

 

0.125

 

 

 

0.5 to 3.0

 

0.25

 

 

 

3.0 to 6.0

 

0.5

 

 

 

6.0 to 24.0

 

2.0

 

 

24 to maximum for scanner

4.0

 

 

 

When you have finished setting up the new scale, press ENTER to return to the Radar Set Up Menu, and press the ON soft key to select your new scale.

Bearing Alignment

The bearing alignment is normally set when you first install your system, and is described in Radar System Checks and Adjustments on page 8-17.

The bearing alignment corrects for display azimuth error. It can be set to a value in the range -180° to +179.5°, in increments of 0.5°.

Antenna Size

This option is used to specify the size of an open array scanner. Refer to the Pathfinder Scanner Owner’s handbook for further details.

Send on HSB

SEND ON HSB can be used to stop radar data being transmitted on hsb2.

If SEND ON HSB is set to OFF, you can view your radar data on the master display, but not on a repeater display.

Bearing Alignment

Page 171
Image 171
Raymarine Combined Pathfinder Radar manual Bearing Alignment, Antenna Size, Send on HSB, Radar Range Scale Increments