Raymarine Chartplotter RL70CRC PLUS System Connections, Grounding the System, DC Power Connection

Models: Raychart Chartplotter RC530 PLUS Combined Pathfinder Radar Chartplotter RL70CRC PLUS RL80CRC PLUS

1 248
Download 248 pages 49.49 Kb
Page 190
Image 190

System Connections

8-12

hsb2 PLUS Series Color LCD Display

8.6 System Connections

Grounding the System

It is important that an effective RF ground is connected to the system. You must ground the display by connecting the drain wire (shield) of the Power/ NMEA Input cable to the nearest ground point of the ship’s RF ground system.

If you need to extend the wire, the extension wire should be an 8 mm braid or AWG 10 (6.0 mm2) multi-stranded cable.

If your vessel does not have an RF system, connect the drain wire to the negative battery terminal.

DC Power Connection

The hsb2 series display is intended for use on ships’ DC power systems rated at 12 V, 24 V or 32 V. However, the operating voltage of the radar and radar/ chartplotter displays is limited by the scanner to which it is connected as follows:

12 V and 24 V systems

Radome Scanner System

12 V, 24 V or 32 V

4 kW Open Array Scanner System;

 

RC530/RC631

24 V or 32 V

10 kW Open Array Scanner System

The power connection to the display should be made at either the output of the battery isolator switch, or at a DC power distribution panel. Raymarine recommends that power is fed directly to the display via its own dedicated cable system and MUST be protected by a thermal circuit breaker or fuse, installed close to the power connection.

The DC system should be either:

Negative grounded, with the negative battery terminal connected to the ships ground.

Floating, with neither battery terminal connected to the ships ground.

CAUTION:

This system is not intended for use on “positive” ground vessels.

The power cable Ground (earth) connections must be connected to the ship’s ground as described above.

Power for External Equipment

External equipment cannot be powered from the display’s SeaTalk interface.

It must be powered from the ship’s supply or via a SeaTalk bus.

Refer to Section 8.8 for further details.

Page 190
Image 190
Raymarine Chartplotter RL70CRC PLUS, RL80CRC PLUS manual System Connections, Grounding the System, DC Power Connection