Raymarine Combined Pathfinder Radar, RL80CRC PLUS manual Selecting the Display Unit Location

Models: Raychart Chartplotter RC530 PLUS Combined Pathfinder Radar Chartplotter RL70CRC PLUS RL80CRC PLUS

1 248
Download 248 pages 49.49 Kb
Page 183
Image 183

Chapter 8: Installation

8-5

 

 

8.3 Selecting the Display Unit Location

The display unit can be mounted using the mounting bracket supplied, or console mounted using the optional flush-mounting kit.

The dimensions of the display units, including the bracket, are shown in Figure 8-3and Figure 8-4.

When planning the display installation, the following should be considered to ensure reliable and trouble free operation:

Convenience: The contrast and colors seen on all LCD displays vary slightly with viewing angle; this is more noticeable on the left hand side. Power the unit and select a suitable mounting location prior to installing the display.

The mounting location should be easily accessible to allow operation of the front panel controls.

Access: There must be sufficient space behind the display to allow cable connections to the rear panel connectors, avoiding tight bends in the cable.

Interference: The selected location should be far enough away from devices that may cause interference, such as motors, generators and radio transmitter/receivers (see the EMC guidelines earlier in this section).

Magnetic compass: Mount the display unit at least 3 ft (1m) away from a magnetic compass.

Cable runs: The display unit must be located near a DC power source. The power cable supplied is 4.9 ft. (1.5m), but a longer cable can be used if required: refer to Section 8.4.

The maximum length of cable between a master display and the scanner unit should not normally exceed 60 ft. (20 m). If you need to use a longer cable, refer to the Pathfinder Radar Scanner Owner’s Handbook.

Environment: Do not restrict airflow at the rear of the display unit; the display incorporates Cold Cathode Florescent Lamps (CCFL), which have a reduced light output when the unit is very hot.

Ensure there is adequate ventilation, particularly if the display unit is pod-mounted. The display should be protected from physical damage and excessive vibration. Although the display unit is waterproof, it is good practice to mount it in a protected area away from prolonged and direct exposure to rain and salt spray.

Selecting the Display Unit Location

Page 183
Image 183
Raymarine Combined Pathfinder Radar, RL80CRC PLUS, Raychart Chartplotter RC530 PLUS Selecting the Display Unit Location