Raymarine Raychart Chartplotter RC530 PLUS, RL80CRC PLUS Radar Set Up Parameters, EBL Display

Models: Raychart Chartplotter RC530 PLUS Combined Pathfinder Radar Chartplotter RL70CRC PLUS RL80CRC PLUS

1 248
Download 248 pages 49.49 Kb
Page 169
Image 169

Chapter 7: Setting Up the System Defaults

7-11

 

 

7.4 Radar Set Up Parameters

The RADAR SET UP option allows you to set up the radar according to your system configuration and your personal preferences.

Note: Some parameters can only be changed if you are using the Master dis- play (that is, the display to which the scanner is connected).

The following table lists the Radar Set Up parameters and their options, shows the factory default setting, and provides a space for you to make a note of your new default setting. Each parameter is described in the fol- lowing subsections.

Table 7-2:

Radar Set Up Parameters

 

 

 

 

 

 

 

 

 

 

 

 

Parameter

 

Options

 

 

Factory Default

New Default

 

 

 

 

 

 

 

EBL DISPLAY

 

MAG/TRUE, RELATIVE

RELATIVE

 

 

 

 

 

 

 

 

 

 

 

 

TIMED

 

OFF, ON

 

 

OFF

 

 

 

TRANSMIT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANSMIT PERIOD

10 scans, 20 scans, 30 scans

20 scans

 

 

 

 

 

 

 

 

 

STANDBY PERIOD

3, 5, 10 or 15 mins

10 minutes

 

 

 

 

 

 

 

 

 

 

 

 

 

SetRadarUp Parameters

DEFAULT MARK

 

 

 

 

 

 

SYMBOL

 

,

,

,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MARK DISPLAY

 

OFF, ON

 

 

ON

 

 

 

 

 

 

 

 

 

 

CLEAR MARKS

 

Press soft key to clear marks

N/A

 

 

 

 

 

database

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CUSTOM SCALE

OFF, ON,SET RANGES...

OFF

 

 

 

 

 

 

 

 

 

 

 

BEARING

 

Slider value

 

 

 

 

ALIGNMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ANTENNA SIZE

 

4 ft., 6ft (only if an open array

4 ft.

 

 

 

 

 

scanner is connected)

 

 

 

 

 

 

 

 

 

 

 

 

 

SEND ON HSB

 

ON, OFF

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

EBL Display

The mode of the bearing data displayed for Electronic Bearing Lines (EBLs). The bearing information can be displayed in either of two forms:

Relative: The bearing relative to your vessel’s heading.

Mag/True: The actual bearing in either degrees magnetic or degrees true. This option is only available if you are obtaining data from a compass.

If you choose this mode, the selection you made for Bearing Mode determines whether °M or °T is displayed in the EBL data boxes. The current units are shown for the heading value in the status bar at the top of the screen.