8Sun Crypto Accelerator 4000 Board Installation and User’s Guide May 2003
LED Displays

See TABLE1-5.

Note – The service pack numbers (SP9 or SP1) are implied whenever Sun ONE Web

Server 4.1 or 6.0 is mentioned.

TABLE1-5 Front Panel Display LEDs for the UTP Adapter
Label Meaningif Lit Color
Fault Onwhen the board is HALTED (fatal error)
state or low level hardwareinitialization
failed.
Flashing if an erroroccurred during the
boot process.
Red
Diag On in POST,DIAGNOSTICS, and
FAILSAFE(firmware not upgraded) state.
Flashing when running DIAGNOSTICS.
Green
Operate On in POST,DIAGNOSTICS, and
DISABLED (driver not attached) state.
Flashing in IDLE, OPERATIONAL,and
FAILSAFEstates.
Green
Init On if the security officerhas initialized the
boardwith vcaadm. See “Initializing the
Sun Crypto Accelerator 4000 BoardWith
vcaadm” on page 65.
Flashing if the ZEROIZE jumper is present.
Green
FIPS Mode On when operating in FIPS 140-2 level 3
certifiedmode. Off when in non-FIPS
mode.
Green
1000 Indicates Gigabit Ethernet. Green
Activity (no label) Link is transmitting or receiving. Amber
Link (no label) Link up. Green