PRODUCT PREVIEW

TMS320C6454

Fixed-Point Digital Signal Processor

www.ti.com

SPRS311A –APRIL 2006 –REVISED DECEMBER 2006

7.8.3.5 PLLDIV Ratio Change Status Register

Whenever a different ratio is written to the PLLDIV1 register, the PLLCTRL flags the change in the DCHANGE status register. During the GO operation, the PLL controller will only change the divide ratio SYSCLK1 if SYS1 in DCHANGE is 1. The PLLDIV divider ratio change status register is shown in Figure 7-28and described in Table 7-37.

31

 

16

Reserved

 

 

R-0

 

 

15

1

0

Reserved

 

SYS1

R-0

 

R-0

LEGEND: R/W = Read/Write; R = Read only; -n= value after reset

Figure 7-28. PLLDIV Divider Ratio Change Status Register (DCHANGE) [Hex Address: 029C 0144]

Table 7-37. PLLDIV Divider Ratio Change Status Register (DCHANGE) Field Descriptions

Bit

Field

Value

Description

31:1

Reserved

0

Reserved. The reserved bit location is always read as 0. A value written to this field has no effect.

0

SYS1

 

SYSCLK1 divide ratio has been modified. SYSCLK1 ratio will be modified during GO operation.

 

 

0

SYSCLK1 ratio has not been modified. When GOSET is set, SYSCLK1 will not be affected.

 

 

1

SYSCLK1 ratio has been modified. When GOSET is set, SYSCLK1 will change to the new ratio.

144

C64x+ Peripheral Information and Electrical Specifications

Submit Documentation Feedback

Page 144
Image 144
Texas Instruments TMS320C6454 warranty Plldiv Ratio Change Status Register, SYS1