Control Valve Removal (Fig. 65)

1.Before removing any parts from the control lift valve assembly, park the machine on a level surface, engage the parking brake, lower the cutting units and stop the engine. Remove the key from the ignition switch.

CAUTION

Operate all hydraulic controls to relieve system pressure and avoid injury from pressurized hydraulic oil.Control Valve Installation (Fig. 65)

2.Remove side panels lift hood to gain access to the control valve and relief valve.

Control Valve Removal (Fig. 65)

1.Disconnect hose connections (1, 11, 14, and 15) from hydraulic fittings (2 and 13). Allow hoses to drain to a suitable container.

2.Remove lock nuts (5 and 16). Slide cap screw (4) and washer (3) from the control valve (9).

3.Slide control valve (9) from the support bracket (17) and remove from the unit.

4.Unsnap and remove connecting link assembly (8). Remove valve lever (6) from the control valve (9).

5.Disconnect tube (18) from hydraulic fitting (2). Dis- connect tube (12) from hydraulic fitting (10).

6.Remove hydraulic fittings (2, 10, and 13) and O± rings (21 and 23) from the control valve (9).

Control Valve Installation (Fig. 65)

1.Install O±rings (21 and 23) and hydraulic fittings (2, 10, and 13) to the control valve (9).

2.Install tube (12) to hydraulic fitting (10). Connect tube (18) to hydraulic fitting (24).

3.Install valve lever (6) to the control valve (9) by snapping the connecting link assembly (8) to the valve lever and control valve.

4.Position control valve (9) into unit and slide onto support bracket (17).

5.Slide cap screw (4) into control valve (9) and install washer (3). Secure lock nuts (5 and 16).

6.Connect hose connections (1, 11, 14, and 15) to hy- draulic fittings (2 and 13) and tighten connections.

Relief Valve Removal (Fig. 65)

Note: This procedure may be used if only the relief valve needs removal from the unit.

1.Disconnect hose connection (11) from hydraulic fit- ting (2). Allow hose to drain to a suitable container.

2.Disconnect tube (18) from hydraulic fitting (2). Allow fitting to drain to a suitable container.

3.Remove relief valve body (19) and hydraulic fitting

(2) from tube (12).

4.Remove hydraulic fitting (2), tube (18) and both O± rings (23) from the relief valve body (19).

Relief Valve Installation (Fig. 65)

Note: This procedure may be used if only the relief valve has been removed from the unit.

1.Install hydraulic fitting (2) and O±ring (23) to the re- lief valve body (19).

2.Install tube (18) and O±ring (23) to the relief valve body (19).

3.Set relief valve body (19) and attachments into the unit.

4.Connect tube (18) to hydraulic fitting (2).

5.Connect tube (12) to hydraulic fitting (2).

6.Connect hose connection (11) to hydraulic fitting

(2).