Toro 2300-D Cutting Unit Solenoid Valve Coil, Removal, Installation, Loctite, Electrical System

Models: 2600D 2300-D

1 186
Download 186 pages 43.39 Kb
Page 148
Image 148
Loctite 242

Cutting Unit Solenoid Valve Coil

The solenoid valve coil can be easily replaced without opening the hydraulic system.

Removal

1.Disconnect the electrical connector.

2.Remove the nut from the spool assembly.

3.Slide the coil assembly and O±rings from the spool assembly. Discard the coil assembly and O±rings.

4.Clean any corrosion or dirt from the spool assembly.

Installation

1.Coat new O±rings lightly with petroleum jelly. Slide new O±rings and new coil assembly onto the spool as- sembly. Align the coil assembly evenly with the manifold body.

2.Apply Loctite 242 or equivalent to the threads. Screw the nut onto the spool assembly and torque to 15 in±lb (17 KG±CM). Do not over tighten.

3.Connect the electrical connector.

3

 

 

1

3

2

 

 

4

Loctite 242

 

Figure 26

1.

Nut

3.

O±ring

2.

Coil assembly

4.

Spool assembly

Electrical System

Page 5 ± 30

Reelmaster 2300±D/2600±D

Page 148
Image 148