Page 126
Register / Coil Tag Name Read / Write Description
S0022
COM2 failed node
reconnect control
Read/write
If this bit is set communication with the failed
nodes is detected after scan time SW0019 for
port2.By default : ON
S0023 COM3 failed node
reconnect control
Read/write If this bit is set communication with the failed
nodes is detected after scan time SW0022 for
port3. By default : ON
SW64-S65
Node Status Registers
for COM1
Read only
Shows the status of the node, whether node is
present or
not.
Total 2 word Register are mapped
for 32 nodes.
SW66-S79
Node Status Registers
for
COM1
Read only
Shows the status of the node, whether node is
present or not. Total 14 word Register are mapped
for 224 nodes.
SW80-S81 Node Status Registers
for
COM2
Read only Shows the status of the node, whether node is
present or
not.
Total 2 word Register are mapped
for 32 nodes.
SW82-S95 Node Status Registers
for
COM2
Read only Shows the status of the node, whether node is
present or not. Total 14 word Register are mapped
for 224 nodes.
SW96-S111
Node Status Registers
for
COM3
Read only
Shows the status of the node, whether node is
present or not. Total 16 word Register are mapped
for 256 nodes.