5.12OVEN SYSTEMS
Solid State Relay - K1 L1 Speedcook | Thermostat, Cook Cavity |
Heating Elements | To prevent temperature from running away during |
The K1 solid state relay is a 240 VAC, dual 40 amp | normal oven operation, each oven is monitored by |
relay. This relay supplies L1 voltage to the Speedcook | a thermostat (270°F switch for Speedcook cavity |
oven’s heating elements. The control board sends | and 280°F for the lower oven cavity in double wall |
24 VDC to the K1 solid state relay to “open” and | ovens). In both the single and double wall oven, the |
“close” both sides of the solid state relay, which helps | switch(es) are wired to the control board through |
ensure absolute temperature control. | |
| (Gen 2). |
Solid State Relay - K11 Bake and Convection Elements (Double Wall Oven Only)
The K11 solid state relay is a 240 VAC, dual 40 amp relay. This relay supplies L1 voltage to the lower oven’s bake and convection elements (24 VDC control voltage).
Solid State Relay - K12 Broil Elements: Inner and Outer (Double Wall Oven Only)
The K12 solid state relay is a 240 VAC, dual 40 amp relay. This relay controls the L1 voltage to the lower oven’s inner and outer broil elements. The control board sends 24 VDC to the K12 SSR to independently “open” and “close” each side of the SSR, over 100 times per second, for absolute temperature control.
Speaker
The speaker provides audible feedback to the operator whenever a key is pressed or a task (such as a cook cycle) is completed, etc. See page 4.1 for adjustments.
Temperature Switch (Lower Oven)
The temperature switch uses a
Transformer, Clock, 12 VAC
The 12 VAC transformer supplies voltage to the Speedcook oven clock. For Gen 2 ovens, the 12 VAC transformer is located on the relay board (terminals
Thermostat, Cooling Fan Control
The cooling fan control thermostats are normally- open snap switches that will close if the temperature within the upper electrical compartment exceeds 140°F (60°C), or if the temperature within the lower electrical compartment exceeds 160°F (71°C). They supply voltage from the terminal block to the upper and lower cooling fans, allowing them to operate
if they are needed after the CookWheel or selector switch has been turned to the off position. If either thermostat closes, both cooling fans will be powered on.
USB Port
The USB port allows the oven operator to load software updates from a USB drive. For instructions, see page 4.3.
Connecting the USB Board (Gen 1 Oven)
The USB board connects to the control board via a
5.4.Ensure that, when facing the oven, the cable’s red stripe is on your right.
NOTE: The picture below shows the molex cable not completely inserted, ensure you completely insert the molex cable.
Red Stripe