b)Disconnect the following wires from the burner assembly:

Blue and white wires from the flame sensor terminals.

2-wire connector from the ignitor.

2-wire and 3-wire connectors from the coil assembly.

Flame Sensor

Wht & Blu Wires Coil Assembly 2-Wire Connector

3-Wire Connector

Ignitor Connector

c)Disconnect the gas line from the burner manifold at the right rear corner of the dryer.

d)Loosen the burner manifold clamp at the inside back of the dryer.

Manifold Clamp Screw

e)Remove the two hex-head screws from the burner mounting bracket, and pull the burner assembly out of the unit.

Bracket Screws

Burner Assembly

f)To remove the ignitor from the burner assembly, loosen the 5/16 inch hex- head screw, and remove the ignitor from the mounting bracket.

Ignitor Screw

Bracket

 

 

 

 

 

 

 

 

Continued on the next page.

4-19

Page 48
Image 48
Whirlpool MED / GD 9600S, MED / GD 9700S manual Manifold Clamp Screw