REMOVING THE THERMAL FUSE, THERMISTOR,

DRIVE MOTOR, & BELT SWITCH

WARNING

Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Unplug dryer or disconnect power.

2.Turn off gas supply to dryer.

3.Open the dryer door and remove the lint filter screen, then close the door.

Lint Filter Screen

4.Remove the two hex-head screws from the bottom flange of the toe panel. Pull the panel out at the bottom, pull down, and remove the panel.

5.Remove the hex-head screw from the lint duct bracket and remove the bracket.

6.Remove the three hex-head screws from the lint duct and remove the duct.

Lint Duct Screws

7.To remove the thermal fuse or ther- mistor:

a)Remove the two wires from the termi- nals.

b)Remove the two hex-head screws.

Thermal Fuse

(2 Screws)

Thermistor

(2 Screws)

Blower Cover

Toe Panel

Toe Panel Screws

Continued on the next page.