g)To remove the coils from the burner assembly, remove the two screws from the bracket, and lift the two coils off the cores.

Bracket Screws

b)Remove the hex-head screw from the flame sensor and remove the sensor from the venturi.

Screw

Flame Sensor

Coils

5.To remove the flame sensor:

a)Remove the two hex-head screws from the venturi and pull it forward so you can access the flame sensor.

High-Limit Thermostat

Flame Sensor

Venturi Screws

6.To remove the high-limit thermostat:

a)Remove the venturi (see step 5).

b)Disconnect the two wire connectors from the high-limit thermostat.

c)Remove the two hex-head screws from the high-limit thermostat and remove the thermostat.

High-Limit Thermostat

Screw

Screw

Wires

4-20

Page 49
Image 49
Whirlpool MED / GD 9700S, MED / GD 9600S manual To remove the flame sensor, To remove the high-limit thermostat