114 Chapter 12Monitoring & Talkback
02R96—Owner’s Manual
12 Monitoring & Talkback

Control Room Monitoring

The CONTROL ROOM MONITOR OUT uses balanced 1/4-inch
phone jacks, nominal level +4 dB. Typically it’s used to feed the control
room’s main monitors.
The Control Room Monitor signal source is selected by using the CON-
TROL ROOM buttons.
[2TR D1]: Selects the 2TR IN DIGITAL AES/EBU 1.
[2TR D2]: Selects the 2TR IN DIGITAL COAXIAL 2.
[2TR D3]: Selects the 2TR IN DIGITAL COAXIAL 3.
[2TR A1]: Selects the 2TR IN ANALOG 1.
[2TR A2]: Selects the 2TR IN ANALOG 2.
[STEREO]: Selects the Stereo Out.
[ASSIGN 1]: Selects the Output Channel assigned to this button on the Control Room
Setup page. See “Control Room Setup” on page 115.
[ASSIGN 2]: Selects the Output Channel assigned to this button on the Control Room
Setup page. See “Control Room Setup” on page 115.
The level of the Control Room Monitor signal can be set by using the
CONTROL ROOM LEVEL control. The [DIMMER] button activates
the Dimmer function, which dims the Control Room Monitor and Sur-
round Monitor signals by the amount specified on the Control Room
Setup page (page 115). The Dimmer function is activated automatically
when the Talkback or Oscillator function is active.
The Control Room Monitor signal is also fed to the PHONES jack, the level of
which is set by using the PHONES LEVEL control.
CONTROLROOM
2TRD1 2TRA1
2TRD2 2TRA2
2TRD3 STEREO
ASSIGN1ASSIGN2
DIMMER
CONTROLROOM LEVEL
100
TALKBACK
PHONES
LEVEL
010
PHONES