168 Chapter 17MIDI
02R96—Owner’s Manual
Using Bulk Dump
02R96 data can be stored to an external MIDI device, such as a MIDI data filer, by using
MIDI Bulk Dump.
1Use the DISPLAY ACCESS [MIDI] button to locate the Bulk Dump page.
2To transmit data, use the CATEGORY parameters to select the type of data
you want to transmit, select the TRANSMIT button, and then press [ENTER].
3To receive data, use the CATEGORY parameters to select the type of data
you want to receive, select the REQUEST button, and then press [ENTER].
The INTERVAL parameter sets the interval between data packets during transmission.
The CATEGORY parameters can be set as follows:
ALL: All data.
SCENE MEM: ALL Scenes, individual Scenes, or current (i.e., the Edit buffer).
AUTOMIX: ALL Automixes, individual Automixes, or the current Automix.
LIBRARY: The following libraries: EQ, Gate, Comp, Channel, Effects, Bus to Stereo, Input
Patch, Output Patch, Surround Monitor. For each library you can specify ALL user memo-
ries, individual user memories, and for the Bus to Stereo, Input Patch, Output Patch, Sur-
round Monitor libraries you can also specify the current settings.
BANK: User Defined Remote Layer banks, User Defined Plug-Ins banks, or the User
Defined Keys banks. For each item you can specify ALL or individual banks.
SETUP MEM: 02R96 setup data (i.e., system settings).
PGM TABLE: Scene to MIDI Program Change table. See “Assigning Scenes to Program
Changes” on page 166.
CTL TABLE: Parameter to MIDI Control Change table. See “Assigning Parameters to Con-
trol Changes” on page 167.
PLUG-IN: The settings of any installed Y56K cards. You can specify ALL Slots or Slot 3 or 4.