250 Appendix A: Parameter Lists
02R96—Owner’s Manual

COMPAND 5.1

Six input, six output compander for 5.1 surround, with individual solo for each band, and

gain reduction metering of left and right (L+R), left surround and right surround (LS+RS),

center (C), or LFE channels.

Parameter Range Description
LOW GAIN 96.0 to +12.0 dB Low band level
MID GAIN 96.0 to +12.0 dB Mid band level
HI. GAIN 96.0 to +12.0 dB High band level
PRESENCE 10 to +10
For positive values, the threshold of the high band is low-
ered and the threshold of the low band is increased. For
negative values, the opposite will occur. When set to 0, all
three bands are affected the same.
THRE 24.0 dB to 0.0 dB Compressor threshold
RATIO 1:1 to 20:1 Compressor ratio
ATTACK 0120 ms Compressor attack
WIDTH 190 dB Width before the expander operates
TYPE Soft, Hard Compander type
LOOKUP 0.0100.0 ms Lookup delay
CEILING 6.0 dB to 0.0 dB, OFF Species the maximum output level
LM XOVR 21.2 Hz8.00 kHz Low/mid crossover frequency
MH XOVR 21.2 Hz8.00 kHz Mid/high crossover frequency
SLOPE 6 dB to 12 dB Filter slope
KEY LINK 1
1. 5.1: key-in of all inputs are linked. 5.0: key-in of the L, C, R, LS, and RS are linked (LFE is indepen-
dent). 3+2: key-in of L, C, and R are linked, and LS and RS are linked. 2+2: key-in of L and R are
linked, and LS and RS are linked.
Key-in linking