200 Chapter 20Other Functions
02R96—Owner’s Manual
Using the Oscillator
The 02R96 features an oscillator that can be used for calibration or diagnostic purposes.
1Use the DISPLAY ACCESS [UTILITY] button to locate the Oscillator page.
2Use the cursor buttons to select the parameters, and use the Parameter
wheel, INC/DEC button, or [ENTER] button to set them.
OSCILLATOR ON: This turns the Oscillator on or off. While the LEVEL parameter is
selected, the [ENTER] button can be used to turn on and off the Oscillator.
LEVEL: This sets the Oscillator output level, which is displayed by the adjacent meter. This
parameter can be set by using the Parameter wheel regardless of which parameter is cur-
rently selected.
WAVEFORM: These buttons are used to select the waveforms: SINE 100Hz, SINE 1kHz,
SINE 10kHz, PINK NOISE, or BURST NOISE, which is 200 msec pink noise pulses at four
second intervals.
ASSIGN: These buttons are used to assign the Oscillator output to Bus Outs, Aux Sends,
and the Stereo Out.
Checking the Battery
The condition of the internal memory-backup battery can be checked as follows.
1Use the DISPLAY ACCESS [UTILITY] button to locate the Battery Check page.
If the Status is “Okay,” the battery is okay. If the Status is “Getting Low,” ask your Yamaha
dealer to replace the battery as soon as possible. Do not attempt to replace the battery your-
self. Failure to replace a low battery may result in data loss.
Note: To prevent any sudden tone burst surprises in your monitors or headphones, you may
want to set the LEVEL parameter to minimum before turning on the oscillator.