MB02R96 Peak Meter Bridge 289
02R96—Owner’s Manual
Meter Bridge Controls
A Channel indicators
These indicators show which channels are currently being
metered: Input Channels 1–24, 25–48, or 49–56 and Aux Sends
1–8 and Bus Outs 1–8.
B INPUT METERING POSITION button & indicators
This button is used to set the metering position for Input Channels
to pre-EQ, pre-fader, or post-fader. It works in unison with the
PRE EQ, PRE FADER, and POST FADER buttons for Input
Channels on the Meter pages. The indicators show the current set-
ting.
C PEAK HOLD button
This button is used to turn the Peak Hold function on and off. Its
indicator lights up when Peak Hold is on. It works in unison with
the PEAK HOLD buttons on the Meter pages.
D LAYER buttons
These button are used to select Layers for metering. The button
indicator for the currently selected Layer lights up. If the Meter
Follow Layer preference is on (see page 198), these Layers are
selected automatically when the LAYER buttons on the 02R96 are
pressed.
E OUTPUT METERING POSITION button & indicators
This button is used to set the metering position for Output Chan-
nels to pre-EQ, pre-fader, or post-fader. It works in unison with
the PRE EQ, PRE FADER, and POST FADER buttons for Output
Channels on the Meter pages. The indicators show the current set-
ting.
F Meters
These 12-segment LED meters display the signals levels of the
channels on the currently selected Layer.
G STEREO meters
These 32-segment meters display the signal levels of the Stereo
Out.
H CONTROL ROOM button
This button is used to display the level of the Control Room signal
on the STEREO meters. Its indicator lights up when the STEREO
meters are displaying Control Room levels.
I BUS meters
These 12-segment LED meters display Bus Out signal levels.
56
OVER
1
3
4
7
6
8
2
5