12 Chapter 2—Control Surface & Rear Panel
02R96—Owner’s Manual
DISPLAY ACCESS
A PHASE/INSERT button
This button is used to select the Input Channel Phase and Insert pages. See “Reversing the
Signal Phase” on page 59 and “Using Inserts” on page 95 for more information.
B DELAY button
This button is used to select the Delay pages. See “Delaying Channel Signals” on page 101
for more information.
DYNAMICS
A DYNAMICS DISPLAY button
This button is used to select the following pages: Gate Edit, Gate Library, Comp Edit, and
Comp Library. See “Gating Input Channels” on page 60 and “Compressing Channels” on
page 97 for more information.
B GATE ON button
This button is used to turn the currently selected Input Channel’s Gate on and off. Its indi-
cator lights up when the Gate is on. See “Gating Input Channels” on page 60 for more infor-
mation.
C COMP ON button
This button is used to turn the currently selected channel’s Compressor on and off. Its indi-
cator lights up when the Compressor is on. See “Compressing Channels” on page 97 for
more information.
D GATE/COMP button
This button is used to set the rotary controls for either Gate or Compressor operation.
When an Output Channel is selected, Compressor is selected automatically and cannot be
changed. See “Gating Input Channels” on page 60 and “Compressing Channels” on page 97
for more information.
E THRESHOLD, RANGE, ATTACK, DECAY, HOLD (THRESHOLD, RATIO, ATTACK,
RELEASE, GAIN) controls
When the GATE/COMP button is set to GATE, these controls set the Threshold, Range,
Attack, Decay, and Hold parameters of the currently selected Input Channel’s Gate. When
it’s set to COMP, they set the Threshold, Ratio, Attack, Release, and Gain parameters of the
currently selected channel’s Compressor. See “Gating Input Channels” on page 60 and
“Compressing Channels” on page 97 for more information.
F GATE/COMP indicators
These indicators show whether the rotary controls are set to control a Gate or Compressor.
The GATE indicator lights up when they’re set to control a Gate; the COMP indicator, when
DISPLAY ACCESS
PHASE /
INSERT DELAY
1 2
6
2
GATEON COMPON GATE
COMP
RANGE
RATIO
ATTACK
ATTACKTHRESHOLD
THRESHOLD
DYNAMICS
DISPLAY
GATE/ COMP DECAY
RELEASE
HOLD
GAIN
1