Troubleshooting

AUTO SETUPBefore AUTO SETUP

Error message

Cause

Remedy

See

page

 

 

 

Connect MIC!

Optimizer microphone is not connected.

Connect the supplied optimizer microphone

30

 

 

to the OPTIMIZER MIC jack on the front

 

 

 

panel.

 

 

 

 

 

Unplug HP!

Headphones are connected.

Unplug the headphones.

 

 

 

 

Memory Guard!

The parameters of this unit are protected.

Set “MEMORY GUARD” to “OFF”.

84

 

 

 

 

During AUTO SETUP

 

 

 

Error message

Cause

Remedy

See

page

 

 

 

E-1:NO FRONT SP

Front L/R channel signals are not detected.

Check the front L/R speaker connections.

13

 

 

 

 

E-2:NO SUR. SP

A surround channel signal is not detected.

Check the surround speaker connections.

13

 

 

 

 

E-3:NO PRNS SP

A presence channel signal is not detected.

Check the presence speaker connections.

13

 

 

 

 

E-4:SBR.SBL

Only right surround back channel signal is

Connect the surround back speaker to the

13

 

detected.

SURROUND BACK (SINGLE) speaker

 

 

 

terminal if you only have one surround

 

 

 

back speaker.

 

 

 

 

 

E-5:NOISY

Background noise is too loud.

Try running “AUTO SETUP” in a quiet

 

 

environment.

 

 

 

 

 

 

 

Turn off noisy electric equipment like air

 

 

conditioners or move them away from the

 

 

 

optimizer microphone.

 

 

 

 

 

E-6:CHECK SUR.

Surround back speakers are connected,

Connect surround speakers when you use

14

 

though surround L/R speakers are not.

surround back speakers.

 

 

 

 

 

E-7:NO MIC

The optimizer microphone was unplugged

Connect the supplied optimizer microphone

30

 

during the “AUTO SETUP” procedure.

to the OPTIMIZER MIC jack on the front

 

 

 

panel.

 

 

 

 

 

E-8:NO SIGNAL

The optimizer microphone does not detect

Check the microphone setting.

30

 

test tones.

 

 

 

Check the speaker connections and

13

 

 

 

 

placement.

 

 

 

 

 

 

 

The optimizer microphone or OPTIMIZER

 

 

MIC jack may be defective. Contact the

 

 

 

nearest Yamaha dealer or service center.

 

 

 

 

 

E-9:USER CANCEL

The “AUTO SETUP” procedure was

Run “AUTO SETUP” again.

30

 

cancelled due to user activity.

 

 

 

 

 

 

E-10:INTERNAL ERROR

An internal error occurred.

Run “AUTO SETUP” again.

30

 

 

 

 

INFORMATION

ADDITIONAL

 

 

English

113 En