Optimizing the speaker setting for your listening room

Before proceeding next operation

Once you perform the next operation, this unit starts the automatic setup procedure in 10 seconds. For more accurate measurements, we recommended that you get out of the room or move to the wall where speakers are not around during the measurement.

4Press 8ENTER to start the measurement.

Loud test tones are output from each speaker during the measurement. Once all items for the first listening position are measured, the following message appears.

AUTO SETUP

Put the microphone at 2nd listening position

[ENTER]: Next

[p] : Skip

Notes

During the automatic setup procedure, do not perform any operation on this unit.

The measurement is canceled if an error occurs (page 32).

5Move the optimizer microphone to thesecond listening position and then press 8ENTER to start the measurement.

y

To skip the measurements at the remaining listening positions, press 8n.

Reloading the automatic setup parameters

In case you are not satisfied with the speaker setup and sound adjustments made in “MANUAL SETUP”, you can restore the settings back to the values configured by the last automatic setup.

Note

If you reload the automatic setup parameters, the settings you have made in “MANUAL SETUP” are cleared. To save the settings before reloading the automatic setup parameters, see “SYSTEM MEMORY” (page 86).

1Set the operation mode selector to EAMP and then press HMENU.The top “SET MENU” screen appears in the OSD.2Press 8k / n repeatedly to select “AUTO SETUP” and then press 8ENTER.

3Check if “SETUP” is selected and then press 8l / h repeatedly to select “RELOAD”.

4Press 8k / n repeatedly to select “START” and then press 8ENTER.The results of the last automatic setup are displayed.

y

For details about automatic setup results and how to display the setup results in detail, see “Basic automatic setup” (page 30).

6 Repeat step 5 until the measurement at all5 Press 8k / n repeatedly to select “SET” and
listening positions are made.then press 8ENTER.

If you have made the measurement at all listening positions or skipped the measurement at the remaining listening positions, the following message appears.

AUTO SETUP

Measurement Complete

The automatic setup parameters are reloaded.

y

To cancel reloading the automatic setup parameters, press 8l / h repeatedly to select “CANCEL” and then press 8ENTER.

Press [ENTER]

7Follow steps 4 to 10 in “Basic automatic setup” (page 30) to check the setup result and exit from “SET MENU”.