Optimizing the speaker setting for your listening room

6Press 8l / h repeatedly to toggle between the setup result displays.Press 8k/ nto toggle between the parameters in the result.

Number of the measured points

Results of the speaker connection and wiring

Results of the speaker distance from the listening position

Results of the speaker detection and size

Results of the parametric equalizer of each speaker

Results of the speaker output level

y

If you are not satisfied with the results or want to manually adjust each parameter, use “MANUAL SETUP”

(page 74).

You can select the parametric equalizer type with “PEQ SELECT” (page 79).

Notes

The distances displayed in the “DISTANCE” results may be longer than the actual distance depending on the characteristics of your subwoofer or external amplifiers if you connect them.

In the “EQ” results, different values may be set for the same band to provide finer adjustments.

7Press 8ENTER to return to the top result display.

AUTO SETUP

 

RESULT

 

 

MLT :

1

 

SP :

5/4/0.1

 

DIST:

14.0/17.0ft

.

LVL : -10.0/+5.0dB

>SET

CANCEL

[]/[p]: Up/Down

[ENTER]: Enter

8Press 8l / h to select “SET” or “CANCEL” and then press 8ENTER.

AUTO SETUP

 

RESULT

 

 

MLT :

1

 

SP :

5/4/0.1

 

DIST:

14.0/17.0ft

.

LVL : -10.0/+5.0dB

>SET

CANCEL

[]/[p]: Up/Down

[ENTER]: Enter

Choices: SET, CANCELSelect “SET” to confirm the “AUTO SETUP” results.Select “CANCEL” to cancel the “AUTO SETUP” results.9Disconnect the optimizer microphone or press HMENU to exit from "SET MENU".

Note

If you change speakers, speaker positions, or the layout of your listening environment, run “AUTO SETUP” again to recalibrate your system.

If an error screen appearsPress 8l / h to select “RETRY” or “EXIT” and then press 8ENTERThe following screen is an example where “E-9:USER CANCEL” appears in the OSD.

ERROR

E-9:USER CANCEL Don't operate any function

. >RETRY EXIT

[p]/[[]: Select

[ENTER]: Enter

Choices: RETRY, EXITSelect “RETRY” to retry the “AUTO SETUP” procedure.Select “EXIT” to exit from the “AUTO SETUP” procedure.

y

• If “E-5:NOISY” appears, you can also select “PROCEED” to

32 En