88Configuration

Standard Control Panel Parameters

Table 12 • Printer Parameters (Page 20 of 26)

 

Language/Parameter

Action/Explanation

 

 

 

ZPL only

Set Delimiter Character

 

 

The delimiter character is a two-digit hex value used as a parameter place

 

 

 

 

marker in ZPL/ZPL II format instructions. See the ZPL Programming

 

 

Guide for more information.

 

 

Note • Do not use the same hex value for the control, format, and

 

 

delimiter character. The printer must see different characters to

 

 

work properly.

 

 

Default Value: 2C ,

 

 

Range: 00 to FF

 

 

To change the value shown:

 

 

1. Press SELECT to select the parameter.

 

 

2. Press MINUS (-)to move to the next digit position.

 

 

3. Press PLUS (+) to increase the value of the digit.

 

 

4. Press SELECT to accept any changes and deselect the parameter.

 

 

 

ZPL only

Select ZPL Mode

 

 

The printer remains in the selected mode until it is changed by this

 

 

 

 

parameter or by using a ZPL/ZPL II command. The printer accepts label

 

 

formats written in either ZPL or ZPL II, eliminating the need to rewrite any

 

 

ZPL formats that already exist. See the ZPL Programming Guide for more

 

 

information on the differences between ZPL and ZPL II.

 

 

Default Value: ZPL II

 

 

 

 

Range: ZPL II, ZPL

To change the value shown:

1.Press SELECT to select the parameter.

2.Press PLUS (+) or MINUS (-)to toggle between the options.

3.Press SELECT to accept any changes and deselect the parameter.

79695L-002 Rev. A

Z Series®/RZ™ Series User Guide

6/6/08