Configuration 91

Standard Control Panel Parameters

Table 12 • Printer Parameters (Page 23 of 26)

 

Language/Parameter

Action/Explanation

 

 

 

 

 

Adjust Left Position

 

 

 

 

This parameter adjusts the print position horizontally on the label. Positive

 

 

numbers adjust printing to the left by the specified number of dots.

 

 

Negative numbers shift printing to the right.

 

 

Default Value: 0000

 

 

Range: –9999 to +9999 dots

 

 

 

 

To change the value shown:

 

 

1. Press SELECT to select the parameter.

 

 

2. Press MINUS (-)to move the cursor.

 

 

3. Press PLUS (+) to change between +/- and to increase the value of the

 

 

digit. For a negative value, enter the value before changing to the

 

 

minus sign.

 

 

4. Press SELECT to accept any changes and deselect the parameter.

 

 

 

ZPL only

Set Reprint Mode

 

 

When reprint mode is enabled, you can reprint the last label printed either

 

 

 

 

by issuing the ~PR ZPL command or by pressing MINUS (-)on the control

 

 

panel.

 

 

Default Value: DISABLED

 

 

Selections: ENABLED, DISABLED

 

 

 

To change the value shown:

1.Press SELECT to select the parameter.

2.Press PLUS (+) or MINUS (-)to toggle between the options.

3.Press SELECT to accept any changes and deselect the parameter.

6/6/08

Z Series®/RZ™ Series User Guide

79695L-002 Rev. A