90Configuration

Standard Control Panel Parameters

Table 12 • Printer Parameters (Page 22 of 26)

 

Language/Parameter

Action/Explanation

 

 

 

 

 

Select Backfeed Sequence

 

 

 

 

This parameter sets when label backfeed occurs after a label is removed in

 

 

some print modes. It has no effect in Rewind mode. This setting is

 

 

superseded by ~JS when received as part of a label format (see the ZPL

 

 

Programming Guide for more information).

 

 

Default Value: DEFAULT (90%)

 

 

 

 

Selections: DEFAULT, AFTER, OFF, BEFORE, 10%, 20%, 30%, 40%,

 

 

50%, 60%, 70%, 80%

 

 

To change the value shown:

 

 

1.

Press SELECT to select the parameter.

 

 

2.

Press PLUS (+) or MINUS (-)to scroll through the options.

 

 

3.

Press SELECT to accept any changes and deselect the parameter.

 

 

 

ZPL, EPL, APL-D

Adjust Label Top Position

 

 

This parameter adjusts the print position vertically on the label. Positive

 

 

 

 

numbers adjust the label top position farther down the label (away from the

 

 

printhead) by the specified number of dots. Negative numbers adjust the

 

 

position up the label (toward the printhead).

 

 

Default Value: +000

 

 

Range (ZPL, EPL): -120 to +120

 

 

APL-I only

Range (APL-D):–0.64i to 0.64i (when printer is set to operate in inches)

 

 

Range (APL-I): –10 to 4000

 

 

 

 

To change the value shown:

 

 

1.

Press SELECT to select the parameter.

 

 

2.

Press PLUS (+) to increase the value.

 

 

3.

Press MINUS (-)to decrease the value.

 

 

4.

Press SELECT to accept any changes and deselect the parameter.

 

 

 

APL-I only

Adjust Label Left Position

 

 

The label left position adjusts the print position horizontally on the label.

 

 

 

 

Positive numbers move the left edge of the image toward the center of the

 

 

label by the number of dots selected while negative numbers shift the left

 

 

edge of the image toward the left edge of the label.

 

 

Default Value: +0000

 

 

Range: –9999 to +9999

 

 

To change the value shown:

1.Press SELECT to select the parameter.

2.Press PLUS (+) to increase the value.

3.Press MINUS (-)to decrease the value.

4.Press SELECT to accept any changes and deselect the parameter.

79695L-002 Rev. A

Z Series®/RZ™ Series User Guide

6/6/08