Calibrate the Printer

76

Operations

Calibrate the Printer

Calibrate the Printer

Calibrate the printer when it is first put into service. Calibration allows the printer to establish the proper settings for the specific media and ribbon used in your application. You may calibrate the printer at other times as needed. Table 7 shows the different methods for calibration.

Important • To retain calibration settings in the printer’s memory when the printer is power cycled, you must save the changes permanently. See Exit Setup Mode on page 87.

Table 7 • Types of Calibration

Type of Calibration

Description

When/How It Occurs

 

 

 

Auto-calibration

The printer automatically sets the value

Occurs at the following times:

 

it detects for the spaces between labels.

• When the printer is first turned on if

 

 

CALIBRATION is selected for

 

 

MEDIA POWER UP (see Select

 

 

Media Power-Up Option

 

 

on page 105).

 

 

• When the printer feeds media after

 

 

the printhead is closed if

 

 

CALIBRATION is selected for

 

 

HEAD CLOSE (see Select Head

 

 

Close Option on page 106).

 

 

• As part of both the sensor profile and

 

 

media and ribbon sensor calibration

 

 

procedures.

 

 

 

Long Calibration

The printer does the following:

To perform a long calibration, do one of

 

• feeds media and ribbon

the following:

 

• sets the values it detects for media

• Press PAUSE on the control panel to

 

length, media type (continuous or

pause the printer, and then press

 

non-continuous), and print mode

CALIBRATE.

 

(thermal transfer or direct thermal)

• Select CALIBRATION for the

 

• updates the sensor values

MEDIA POWER UP or HEAD

 

 

CLOSE parameter (see Select Media

 

 

Power-Up Option on page 105 or

 

 

Select Head Close Option

 

 

on page 106).

 

 

 

Short Calibration

The printer calibrates using the current

Select SHORT CAL for the MEDIA

 

sensor values rather than detecting the

POWER UP or HEAD CLOSE parameter

 

spaces between labels and resetting the

(see Select Media Power-Up Option

 

sensors. This calibration sequence uses

on page 105 or Select Head Close

 

fewer labels than the long calibration

Option on page 106.

 

sequence, but it is less reliable because

 

 

the values that are stored in the sensors

 

 

could be incorrect.

 

 

 

 