8.Press down on the loops to lock the snap plate into place.

126

Routine Maintenance

Cleaning Schedule and Procedures

6.Using the swab from the Preventive Maintenance Kit (part number 47362), clean the back of the snap plate. In place of the Preventive Maintenance Kit, you may use a clean swab or soft cloth dipped in a solution of isopropyl alcohol (minimum 90%) and deionized water (maximum 10%). Allow the solvent to evaporate.

7.To reinstall the snap plate, insert the two tabs on the bottom of the snap plate into the two slots of the media path.

8.Press down on the loops to lock the snap plate into place.

9.Reinstall the media and ribbon (if used).

10.Reconnect the data cables and AC power cord, and turn on (l) the printer.