108

Configuration

Standard Control Panel Parameters

Table 8 • Printer Parameters (Sheet 18 of 22)

Language/Parameter

Action/Explanation

Set the Verifier Port

The auxiliary port is used to determine how the printer reacts to an online verifier. For more information on the operation of the optional verifier, refer to the documentation provided with that option.

Default: OFF

Selections: OFF, VER-RPRNT ERR, VER-THRUPUT

OFF: The verifier port is off.

VER-RPRNT ERR: Label reprinted if verifier detects an error. If a bar code is near the upper edge of the label, the label is fed out far enough to be verified and then backfed to allow the next label to be printed and verified.

VER-THRUPUT:Allows greatest throughput but may not indicate a verification error immediately upon detection. May print from one to three labels before an error is recognized and printing stops.

To change the value shown:

1.Press PLUS (+) or MINUS (-)to scroll through the options.

Set Applicator Port Mode

Determines the action of the applicator port.

Note • Set this value as suggested by the applicator manufacturer.

Default: OFF

Selections: OFF, MODE 1, MODE 2, MODE 3, MODE 4

OFF: The applicator port is off.

MODE 1: Asserts the ~END_PRINT signal low while the printer is moving the label forward.

MODE 2: Asserts the ~END_PRINT signal high while the printer is moving the label forward.

MODE 3: Asserts the ~END_PRINT signal low for 20 milliseconds when a label has been completed and positioned. Not asserted during continuous printing modes.

MODE 4: Asserts the ~END_PRINT signal high for 20 milliseconds when a label has been completed and positioned. Not asserted during continuous printing modes.

To change the value shown:

1.Press PLUS (+) or MINUS (-)to scroll through the options.

P1009874-002

Xi4™/RXi4™ User Guide

1/7/10

Page 108
Image 108
Zebra Technologies 22080100000, XI4TM, 14080100200 108, Printer Parameters Sheet 18, Set the Verifier Port, Default OFF