Table 8 • Printer Parameters (Sheet 16 of 22)

106

Configuration

Standard Control Panel Parameters

Table 8 • Printer Parameters (Sheet 16 of 22)

Language/Parameter

Action/Explanation

Select Head Close Option

This parameter sets the action of the media when you close the printhead.

Default Value (non-RFID printers): CALIBRATION

Default Value (RFID printers): FEED

Selections: CALIBRATION, LENGTH, SHORT CAL, NO MOTION,

FEED

Calibration adjusts sensor levels and thresholds, determines length, and feeds the media to the next web.

Short Cal sets media and web thresholds without adjusting sensor gain, determines length, and feeds the media to the next web.

Length determines label length using current sensor values, and feeds the media to the next web.

No Motion tells the printer not to move the media. You must manually ensure that the web is positioned correctly, or press feed to position the next web.

Feed—feeds the labels to the first registration point.

To change the value shown:

1.Press PLUS (+) or MINUS (-)to scroll through the options.

Select Backfeed Sequence

This parameter sets when label backfeed occurs after a label is removed in some print modes. It has no effect in Rewind mode. This setting is superseded by ~JS when received as part of a label format (see the Programming Guide for ZPL, ZBI, Set-Get-Do, Mirror, and WML for more information).

Default Value: DEFAULT (90%)

Selections: DEFAULT, AFTER, OFF, BEFORE, 10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%

To change the value shown:

1.Press PLUS (+) or MINUS (-)to scroll through the options.

Adjust Label Top Position

This parameter adjusts the print position vertically on the label. Positive numbers adjust the label top position farther down the label (away from the printhead) by the specified number of dots. Negative numbers adjust the position up the label (toward the printhead).

Default Value: +000

Range: -120 to +120

To change the value shown:

1.Press PLUS (+) to increase the value.

2.Press MINUS (-)to decrease the value.