Configuration

Standard Control Panel Parameters

Table 8 • Printer Parameters (Sheet 17 of 22)

Language/Parameter

Action/Explanation

Adjust Left Position

This parameter adjusts the print position horizontally on the label. Positive numbers adjust printing to the left by the specified number of dots. Negative numbers shift printing to the right.

Default Value: 0000

Range: –9999 to +9999 dots

To change the value shown:

1.Press MINUS (-)to move the cursor.

2.Press PLUS (+) to change between +/- and to increase the value of the digit. For a negative value, enter the value before changing to the minus sign.

Set the Head Test Count

The printer periodically performs a test of the printhead functionality, called a printhead test or head test. This parameter establishes how many labels are printed between these internal tests.

Note • On the 110Xi4, this parameter appears only if the Head Test Count option is installed. Check the printer configuration label for the option.

Default: 0000 (disables the test)

Range: 0000 to 9999

To set the number of labels to print between head tests:

1.Press MINUS (-)to move to the next digit position.

2.Press PLUS (+) to increase the value of the digit.