Routine Maintenance

Replace the Fuse

Replace the Fuse

The instructions that follow are for the 140Xi4, 170Xi4, and 220Xi4 printers only. Fuses are not user-replaceable in the 110Xi4.

Caution • Turn the AC power switch off (O) and remove the power cord before performing this procedure.

131

The printer uses a metric-style fuse (5 × 20 mm IEC) rated at F5A, 250 V. The AC power entry module comes with two approved fuses in the fuse holder: one is in-circuit, and the second is provided as a spare. The end caps of the fuse must bear the certification mark of a known international safety organization (see Figure 5 on page 29).

To replace a faulty fuse, complete these steps:

1.Caution • Turn off (O) the printer and disconnect it from the power source before performing the following procedure.

Turn off (O) the printer, and disconnect the AC power cord and all data cables.

2.Use a small-blade screwdriver or similar tool to remove the fuse holder.

The fuse holder is part of the AC power entry module at the rear of the printer (Figure 21).

Figure 21 • AC Power Entry Module

1

2

3 4

1Power switch

2Fuse holder

3AC power entry module

4Small-blade screwdriver

3.Remove the faulty fuse and install a new fuse in the in-circuit position (Figure 22).

Important • If you use the spare fuse, be sure to order a replacement fuse from an authorized Zebra distributor. The spare fuse should be the exact type and rating as the original in-circuit fuse.

1/7/10

Xi4™/RXi4™ User Guide

P1009874-002

Page 131
Image 131
Zebra Technologies 14080100200, RXI4TM manual Replace the Fuse, 131, To replace a faulty fuse, complete these steps