GROUNDING INSTRUCTIONS

This compressor should be grounded while in use to protect the operator from electric shock. The compressor is equipped with a three-conductor cord and three-prong grounding type plug to fit the proper grounding type receptacle. The green (or green and yellow) conductor in the cord is the grounding wire. Never connect the green (or green and yellow) wire to a live terminal. If your unit is for use on less than 150 volts, it has a plug that looks like that shown in sketch (A) in Figure on the right. An adapter, see sketches (B) and (C), is available for connecting sketch (A) type plugs to two-prong receptacles. The green-colored rigid ear, lug, or the like extending from the adapter must be connected to a permanent ground, such as a properly grounded outlet box.

NOTE: The grounding adaptor, sketch (C), is prohibited in Canada by Canadian Electrical Code Part 1. Therefore, the instructions for its use are not applicable in Canada.

We recommend that you never disassemble the compressor or try to do any rewiring in the electrical system. Any repairs should be performed only by HITACHI Service Centers or other qualified service organizations. Should you be determined to make a repair yourself, remember that the green colored wire is the “grounding” wire. Never connect this green wire to a “live” terminal. If you replace the plug on the power cord, be sure to connect the green wire only to the grounding (longest) prong on a 3-prong plug.

If in doubt, call a qualified electrician and have the receptacle checked for ground.

English

Cover of

grounded outlet

Groundbox (A) blade

Cover of grounded outlet box (B)

Adapter

Grounding means (C)

SAVE THESE INSTRUCTIONS

AND

MAKE THEM AVAILABLE TO OTHER USERS OF THIS TOOL!

— 7 —

Image 7
Contents Advertencia AvertissementContents Important Information Meanings of Signal WordsSafety Check Damaged Parts and AIR Leak Keep Motor AIR Vent CleanOutdoor USE Extension Cords Stay AlertDo not Stop Compressor by Pulling OUT the Plug Replacement PartsGrounding Instructions Name of Parts Operation and MaintenanceApplications SpecificationsPrior to Operation Pre-start checklist Air coupler installationStart up Adjustment of working pressureTransport OperationShutdown MaintenanceAbout the thermal protector Belt tension Cleaning the filter elementDraining air tank Oil change-oil topping offMaintenance chart Service and RepairsInformations Importantes Signification DU Vocabulaire DE SignalisationBien Lire Toutes LES Instructions SécuritéRester SUR SES Gardes SE Vêtir CorrectementFaire Attention AU Cordon Cordons DE Rallonge Pour Utilisation À L’EXTÉRIEURNE PAS Arreter LE Compresser EN Debranchant SA Fiche Pièces DE RechangeNE PAS Diriger LE JET D’AIR Directement SUR LE Corps Vidanger LE ReservoirInstructions DE Mise À LA Terre NOM DES Pièces Utilisation ET EntretienAvant L’UTILISATION Installation initialeEmplacement Installation électriqueListe des vérifications avant la mise en marche Installation du coupleur d’airMise en marche UtilisationArrêt Réglage de la pression de travailPropos du protecteur thermique Changement d’huile-renversement d’huile EntretienNettoyage de l’élément de filtre à air Vidange du réservoir d’airTension de la courroie Service APRÈS-VENTE ET RéparationsTableau d’entretien Significado DE LAS Palabras DE Señalización Información ImportanteLEA Todas LAS Instrucciones SeguridadEsté Atento Mantenga Alejadas a LAS VisitasVestir Adecuadamente No Maltrate EL CableLA Válvula DE Seguridad Debe Funcionar Correctamente Piezas DE ReemplazoVaciar LA Cámara DE Aire No Detenga EL Compresor Sacando EL EnchufeInstrucciones Para LA Puesta a Tierra Nomenclatura Operación Y MantenimientoAplicaciones EspecificacionesAntes DE LA Operación Lista de comprobación previa Instalación del conector de aireOperación TransportePuesta en marcha Apagado Ajuste de la presión de trabajoAcerca del protector térmico Cambio y llenado del aceite MantenimientoLimpieza del filtro Purga de la cámara de aireTensión de la correa Servicio Y ReparacionesEsquema de mantenimiento Page Kestrel Road Mississauga on L5T 1Z5 Steve Reynolds Blvd Norcross, GA