Schumacher 85-8100 Basic Operation, Overload Protection, Battery Charge Acceptance Test

Page 11

DO NOT attempt to start a vehicle without the battery properly installed. Damage may result to the vehicle’s electrical system.

7.5OVERLOAD PROTECTION

The charger uses an output circuit breaker and a thermal breaker to prevent overheating and damage to the charger and the vehicle. If after repeated starting attempts, the charger does not indicate any output on its meter, it may be because one of the two breakers has opened. If the output breaker opens due to excessive current, a popping noise will be heard. It will automatically reset itself in a few minutes. If the thermal breaker opens, it will automatically reset itself in about 15 to 30 minutes. Output over-voltage will show as 19.9 and the FAIL LED will light.

7.6Display and Accuracy Voltage

Open circuit voltage between 12.0–13.0 is displayed to 0.1 V and is accurate to +/- 0.1 V at DC levels.

Open circuit voltage below 12.0 or above 13.0 is displayed to 0.1 V and is accurate to +/- 2%.

Charging voltage is displayed to 0.1 V and is accurate to +/- 2%.

Current

Below 10 A, current is displayed to 0.1 A and is accurate to +/- 0.3 A.

At 10 A or above, current is displayed to 0.1 A and is accurate to +/- 5% Amp Hours

Amp Hours are measured in whole units and represent the charge sent to the battery

NOTE: This is NOT a measurement of actual battery amp hours, but a running display of how many amp hours the battery is currently accumulating.

Charge Time

In Battery Test Mode, the timer displays a countdown timer from 15 minutes to zero.

In Battery Charge Mode, the timer displays a total elapsed time.

8.BASIC OPERATION

8.1BATTERY CHARGE ACCEPTANCE TEST

NOTE: This is NOT the same as a conductance test, for which the battery analyzers mentioned in paragraph 7.4 are used.

a.With charger unplugged, set both dials to test mode (point to white battery illustration boxes on each dial).

b.Hook the cables to battery, red to positive (+) post and black to negative (-) post. (If polarity is reversed, attaching the second clamp will cause a spark. Reverse the clamps.) The battery voltage will appear on the front panel display, and the PASS/FAIL LEDs will blink alternatively until the 15 minute test time elapses.

▪ 11 ▪

Image 11
Contents 85-8100 Page Table of Contents Napa 85-8100 Digital Wheel Charger Important Safety InstructionsPersonal Precautions Attaching the Charger Handle Attaching the HANDLE, Grounding and AC Power Cord ConnectionAC input rating, amperes AWG size of cord Equal to or Charger Location Preparing to Charge BatteryDC Connection Precautions Timer Switch Charger Features and ControlsControl Center Features Engine Start RATE/VOLTAGE Control SwitchOverload Protection Battery Charge Acceptance TestBasic Operation Battery Charge See for more information AS Soon AS Possible After Hooking Cables to BatteryElectrical Condition of the Battery Battery Charging Formula Parallel Charging Multiple Battery ChargingStarter and Charging Systems Test Procedures Charging System Alternator Test Procedure Starter System Test ProcedureLimited Warranty Maintenance InstructionsTroubleshooting DSR Professional Products Customer ServiceManuel D’INSTRUCTIONS Page Tableau DE Temps DE Chargement Table DES MatièresAvertissement Danger DÛ AUX GAZ Explosifs Manuel d’InstructionsPrécautions Personnelles Assemblage DU Chargeur POIGNÉE, Mise À TERRE, Cordon C.A Installation DE LA Poignée AU ChargeurPage Préparation Pour Charger LA Batterie Emplacement DU ChargeurDispositifs DU Centre DE Contrôles Précautions Pour LE Branchement C.CContrôles ET Dispositifs DU Chargeur Commutateur DE RÉGIME/TENSION Commutateur DU MinuteurProtection Contre LA Surcharge Démarrage DU Moteur’APPOINT Fonctionnement BasicTest D’ACCEPTATION DE LA Charge DE Batterie Page Page Formule DE Chargement DE Batterie Condition Électrique DE LA BatterieChargement EN Parallèle Chargement DE Plusieurs BatteriesProcédé DU Test DU Système DE Charge Alternateur Procédé DU Test DU Système DE Démarrage16. Dépannage Secours Instructions D’ENTRETIENGarantie Limitée Service AU ClientPage Cargador Probador Profesional de Baterías Page Tabla DE Duración DE LA Carga ÍndiceAtención Riesgo DE Gases Explosivos Instrucciones Importantes DE SeguridadPrecauciones Personales Instalación DE LA Manija MANIJA, Conexión a TIERRA, Cable EléctricoAdaptador Ubicación DEL Cargador Preparación Para Cargar LA BateríaCaracterísticas DEL Centro DE Control Precauciones Para LA Conexión DE CCCaracterísticas Y Controles DEL Cargador Conmutador DE Control DE VOLTAJE/RÉGIMEN Conmutador DE TiempoProtección Contra Sobrecargas Arranque DE MotorCarga DE Refuerzo Funcionamiento BásicoPrueba DE Aceptación DE LA Carga Page 12. Fórmula DE Carga DE Batería Condición Eléctrica DE LA BateríaCarga EN Paralelo Carga DE Baterías MúltiplesProcedimiento DE Prueba DEL Sistema DE Carga Alternador Procedimientos DE LA Prueba DEL ArrancadorLocalización DE Averías Instrucciones DE MantenimientoServicio AL Cliente Garantía Limitada