Premier Floors manual Panel Span ft

Page 40
Panel Span (ft.)

40

Panel Core

Deflection

 

 

 

 

Panel Span (ft.)

 

 

 

 

Thickness

4’

8’

10’

12’

14’

16’

18’

20’

22’

24’

 

 

L/360

99

38

28

21

16

10

 

 

 

 

3 1/2”

L/240

151

54

43

32

24

16

NA

NA

NA

NA

 

L/180

154*

61*

57

45

34

21

 

 

 

 

 

L/360

102

49

38

30

24

18

14

11

 

 

5 1/2”

L/240

159

78

57

45

32

28

22

16

NA

NA

 

L/180

166*

80*

60*

46*

40*

34*

29

21

 

 

 

L/360

119

59

60

41

34

26

20

15

 

 

7 1/4”

L/240

160*

84

75*

60

50

39

31

23

NA

NA

 

L/180

160*

85*

75*

69*

60*

50*

41

31

 

 

Maximum Floor Span

Maximum Roof Span

Transverse Load Chart 3:

Premier SIPs Type S (Spline)

Transverse Load Chart (psf)

Image 40
Contents installation guide Introduction Table of Contents PBS SIPs Tips Do not put plumbing inside SIPs Fill all voids with expanding foamStorage & Handling Checklist of Tools Spline Connection Lumber Connection I-JoistConnection Panel Basics - Assembly Fasteners Field FabricationPage Field Fabrication Rake/Gable Walls Floors Page PANEL TIP Stagger your panel placement with two panels on one side of the beam, four panels on the other side, and four back on the first side of the beam. This will help your beam stay straight Sill Plates Page Walls STEP 2. LAYOUT TRANSFER STEP 3. PANEL TILTSTEP 4. ADJACENT PANEL STEP 5. FASTENING STEP 6. TOP PLATEHeaders Page Intermediate Floors Page Roofs On the Ground Lifting PanelsPage Page Insul-Lam Electrical Where walls terminate against a panel you can drill at the horizontal electricalPlumbing Shearwalls Premier Panel R-Values Panel Core Panel Core Panel Span ft Panel Core Panel Core Panel Core Panel Core Load Chart Header Header Insul-BeamII Header LoadsPremier Load ChartNo. of Panel Panel Minimum Load Chart 12 Wind Pressure Chart 1 ofSpeed Load Chart 12 Wind Pressure Chart 2 ofSpeed Page REGIONAL FIELD OFFICES NORTHWEST 4609 70th Ave. East Fife, WASOUTHWEST 3434 W. Papago St. Phoenix, AZ