Premier Floors manual Pressure Chart 2 of, Load Chart 12 Wind, Speed

Page 54
Pressure (Chart 2 of

54

Wall Loads (psf) - End Zone (Zone 5) for 100sf to 500sf effective wind area

Mean Roof

 

130 MPH

 

 

140 MPH

 

 

150 MPH

 

 

170 MPH

 

Height (ft)

Exp B

Exp C

Exp D

Exp B

Exp C

Exp D

Exp B

Exp C

Exp D

Exp B

Exp C

Exp D

15

-31.6

-38.2

-46.5

-36.7

-44.4

-53.9

-42.1

-50.9

-61.9

-54.1

-65.5

-79.5

 

 

 

 

 

 

 

 

 

 

 

 

 

20

-31.6

-40.8

-49.0

-36.7

-47.3

-56.9

-42.1

-54.3

-65.3

-54.1

-69.8

-83.9

 

 

 

 

 

 

 

 

 

 

 

 

 

25

-31.6

-42.7

-50.9

-36.7

-49.5

-59.1

-42.1

-56.8

-67.8

-54.1

-73.0

-87.1

 

 

 

 

 

 

 

 

 

 

 

 

 

30

-31.6

-44.2

-52.5

-36.7

-51.4

-60.9

-42.1

-58.9

-69.9

-54.1

-75.7

-89.8

 

 

 

 

 

 

 

 

 

 

 

 

 

35

-33.2

-45.8

-53.7

-38.5

-53.2

-62.4

-44.2

-61.1

-71.6

-56.8

-78.4

-92.0

 

 

 

 

 

 

 

 

 

 

 

 

 

40

-34.4

-47.1

-55.0

-40.0

-54.7

-63.9

-45.9

-62.7

-73.3

-59.0

-80.6

-94.1

 

 

 

 

 

 

 

 

 

 

 

 

 

45

-35.4

-48.3

-56.2

-41.1

-56.2

-65.3

-47.2

-64.4

-74.9

-60.6

-82.8

-96.3

 

 

 

 

 

 

 

 

 

 

 

 

 

50

-36.7

-49.3

-57.2

-42.6

-57.3

-66.4

-48.8

-65.7

-76.2

-62.8

-84.4

-97.9

 

 

 

 

 

 

 

 

 

 

 

 

 

55

-37.6

-50.2

-58.1

-43.7

-58.4

-67.5

-50.1

-66.9

-77.5

-64.4

-86.0

-99.5

 

 

 

 

 

 

 

 

 

 

 

 

 

60

-38.6

-51.2

-59.1

-44.8

-59.5

-68.6

-51.4

-68.2

-78.7

-66.0

-87.6

-101.2

 

 

 

 

 

 

 

 

 

 

 

 

 

Net Design wind

 

-31.6

 

 

-36.7

 

 

-42.1

 

 

-54.1

 

pressure

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure (Chart 2 of

Load Chart 12: Wind

2)

Speed

 

vs.

More information on this chart can be found in Technical Bulletin #15 (www.pbssips.com).

Image 54
Contents installation guide Introduction Table of Contents PBS SIPs Tips Do not put plumbing inside SIPs Fill all voids with expanding foamStorage & Handling Checklist of Tools Spline Connection Lumber Connection I-JoistConnection Panel Basics - Assembly Fasteners Field FabricationPage Field Fabrication Rake/Gable Walls Floors Page PANEL TIP Stagger your panel placement with two panels on one side of the beam, four panels on the other side, and four back on the first side of the beam. This will help your beam stay straight Sill Plates Page Walls STEP 2. LAYOUT TRANSFER STEP 3. PANEL TILTSTEP 4. ADJACENT PANEL STEP 5. FASTENING STEP 6. TOP PLATEHeaders Page Intermediate Floors Page Roofs On the Ground Lifting PanelsPage Page Insul-Lam Electrical Where walls terminate against a panel you can drill at the horizontal electricalPlumbing Shearwalls Premier Panel R-Values Panel Core Panel Core Panel Span ft Panel Core Panel Core Panel Core Panel Core Load Chart Header Header Premier Insul-BeamIIHeader Loads Load ChartNo. of Panel Panel Minimum Pressure Chart 1 of Load Chart 12 WindSpeed Pressure Chart 2 of Load Chart 12 WindSpeed Page SOUTHWEST REGIONAL FIELD OFFICES NORTHWEST4609 70th Ave. East Fife, WA 3434 W. Papago St. Phoenix, AZ