Premier Floors manual Header

Page 46
Header

46

Header

Deflection

 

Header Span (ft.)

 

Depth

 

4’

6’

8’

10’

 

L/480

740*

385*

229*

142*

12”

 

 

 

 

 

L/360

740*

385*

229*

142*

 

 

 

 

 

 

 

L/240

740*

385*

229*

142*

 

 

 

 

 

 

 

L/480

798*

574*

385*

311*

18”

 

 

 

 

 

L/360

798*

574*

385*

311*

 

 

 

 

 

 

 

L/240

798*

574*

385*

311*

 

 

 

 

 

 

 

L/480

886*

629*

429*

361*

24”

 

 

 

 

 

L/360

886*

629*

429*

361*

 

 

 

 

 

 

 

L/240

886*

629*

429*

361*

 

 

 

 

 

 

* indicates ultimate load divided by 3 for the design capacity.

In all cases where a concentrated load is placed over on opening or the design loads exceed the capacity of a panel header, Premier Insul-Beam II should be used if possible or an engineered header assembly is required. More information on this chart can be found in Technical Bulletin #10 (www.pbssips.com).

Continuous over opening

Load Chart 7:

Allowable Header Loads (plf)

Condition 1–Panel is Continuous

Over Opening (No Splines)

Image 46
Contents installation guide Introduction Table of Contents PBS SIPs Tips Do not put plumbing inside SIPs Fill all voids with expanding foamStorage & Handling Checklist of Tools Spline Connection Lumber Connection I-JoistConnection Panel Basics - Assembly Fasteners Field FabricationPage Field Fabrication Rake/Gable Walls Floors Page PANEL TIP Stagger your panel placement with two panels on one side of the beam, four panels on the other side, and four back on the first side of the beam. This will help your beam stay straight Sill Plates Page Walls STEP 2. LAYOUT TRANSFER STEP 3. PANEL TILTSTEP 4. ADJACENT PANEL STEP 5. FASTENING STEP 6. TOP PLATEHeaders Page Intermediate Floors Page Roofs On the Ground Lifting PanelsPage Page Insul-Lam Electrical Where walls terminate against a panel you can drill at the horizontal electricalPlumbing Shearwalls Premier Panel R-Values Panel Core Panel Core Panel Span ft Panel Core Panel Core Panel Core Panel Core Load Chart Header Header Premier Insul-BeamIIHeader Loads Load ChartNo. of Panel Panel Minimum Load Chart 12 Wind Pressure Chart 1 ofSpeed Load Chart 12 Wind Pressure Chart 2 ofSpeed Page SOUTHWEST REGIONAL FIELD OFFICES NORTHWEST4609 70th Ave. East Fife, WA 3434 W. Papago St. Phoenix, AZ