Hose Installation
Pump / Tank Hose Installation: (continued)
3.Connect hose from Pump to Cylinder Control Valve. This will be the small hose connec- tion on thr RH side of the pump (See Figure 10) for this hose, this hose cannot be connected to Cyl. Control valve untill later.
4.Connect Hose from Cutter Valve to Motor. The Hose from the Cutter / Motor Control Valve runs down the Boom using Steel lines and Hoses
(See Figure 12)
5.Connect Return Hose from Motor to Cutter / Motor Control Valve. Connect the hose from the Motor return to the Cutter / Motor Control Valve
(See Figure 12).
6.Return Hose from Cutter Valve to Tank. Connect the return hose from the Cutter / Motor Control valve to the Tank. (See Figure 12). This hose will run down under tractor to the left side. (See Figure 13) anfd then back up the LH side to the Tank. (See Figure 14). The return hose connects to the return Filter Housing (See Figure 15).
7.Return Pressure Gauge. The Return Pres- sure Gauge is a low Pressure Guage that displays uses in Green and Red Fields, Return should stay in the Green when Oil is warm and Tractor is running. (See Figure 15).
|
|
|
|
|
|
|
| Return Hose |
|
|
|
| from Cutter |
|
|
|
| Valve to |
|
| Figure 14 | |||
|
| Tank |
| |
|
|
|
|
|
|
|
|
|
|
Pressure from | Return Hose |
Cutter / Motor | |
Valve to Motor | to Tank |
Return Hose |
|
from Motor |
|
Figure 12 |
|
| Return Hose |
| from Cutter |
| Valve to |
Figure 13 | Tank |
| |
Tank Return Hose to Tank | |
Return Filter Housing | |
Return Hose |
|
Pressure Gauge |
|
Figure 15 |
|
© 2003 | Alamo Group Inc. | Section 7 - 5 |
|