Cylinder Control Valve Installation
REMOTE CABLE OPERATION AND INSTALLATION: (continued)
4.Turn the cable eye Jam nut on the threaded cable end until it bottoms. Thread the Cable Eye onto the cable end until it bottoms on the cable. Turn the eye to align with the spool end and secure the jam nut against the cable eye. (See Figure 6).
5.Slide the cable eye into the slot in the spool and align the holes. Insert the connection pin and install the retaining pin into the hole in the connecting pin and secure by bending both ears of the retaining pin back and around the con- necting pin. (See Figure 7).
6.With the cable attached to the valve, turn the Flange/Sleeve Assembly back onto the threaded cable end until it is flush with the valve face. When turning on the assembly, make sure that the valve spool remains in the neutral position. (See Figure 8).
7.Tighten the Jam Nut onto the Flange/Sleeve Assembly to lock it into position. (See Figure 9)
Figure 6
Figure 7
8.Tighten the Flange into position using the two allen head screws. Use a flat washer to support a lock washer on each bolt. (See Figure 10)
9.Interference will occur between the Flange/ Sleeve Assembly and the casting of the Inlet Section on the Valve Section next to the Inlet Section. To compensate, the provided shims should be placed on the Flange/Sleeve Assem- bly under the flange (See Figure 11)
Figure 8
Figure 9
Figure 10
© 2003 Alamo Group Inc. | Section 8 - 10 |