Bradley Smoker 1734-AENT manuals
Computer Equipment > Network Card
When we buy new device such as Bradley Smoker 1734-AENT we often through away most of the documentation but the warranty.
Very often issues with Bradley Smoker 1734-AENT begin only after the warranty period ends and you may want to find how to repair it or just do some service work.
Even oftener it is hard to remember what does each function in Network Card Bradley Smoker 1734-AENT is responsible for and what options to choose for expected result.
Fortunately you can find all manuals for Network Card on our side using links below.
Bradley Smoker 1734-AENT Manual
170 pages 3.38 Mb
2 Important User Information3 Summary of Changes5 Table of ContentsPreface Chapter 1 About the Adapter Chapter 2 Install the Adapter 10 How To Use This Manual12 Where to Find More Information13 Terminology17 About the Adapter25 Install the Adapter31 Configure the Adapter for Your EtherNet/IP Network43 Configure the Adapter for Direct Connection in RSLogix 5000 Software67 Configure the Adapter for Direct Connection and Rack Optimization in RSLogix 5000 Software89 LED Status IndicatorsWhat This Chapter Contains Read this chapter for information about LED status indicators. Interpret the Status Indicatorsthe 1734-AENT adapter. Series A or B POINT I/O modules will not work with this adapter. 91 A109 BConfigure the RSLinx Ethernet Communication DriverInstall the RSLinx Software What This Appendix 115 C1734 POINT I/O Module/RSLogix 5000 Controller Tag ReferenceWhat This Appendix Read this appendix for information about tag references. 1734 POINT I/O Catalog Numbersthe 1734-AENT adapter. Series A or B POINT I/O modules will not work with this adapter. 116 Valid Number Ranges for RSLogix 5000 Data Types117 Digital 2 POINT Input118 Digital 4 POINT Input119 Digital 2 POINT Output Without Diagnostic Status120 Digital 2 POINT Output With Over Load and Open Load Diagnostic Status121 Digital 2 POINT Output With Over Load Diagnostic Status122 Digital 4 POINT Output With Over Load and Open Load Diagnostic Status123 Digital 4 POINT Output With Over Load Diagnostic Status124 Analog 2 Channel Input133 Analog 2 Channel Output137 Specialty I/O140 Stored DataTo interpret values from -2,147,483,648 to -1, use this conversion Stored Data Tag Value + 4,294,967,296 = Actual Stored Data Tag 141 Program Fault 145 Stored Data To interpret values from -2,147,483,648 to -1, use this conversion Stored Data Tag Value + 4,294,967,296 = Actual Stored Data Tag 149 Present / Latched Data To interpret values from -2,147,483,648 to -1, use this conversion Stored Data Tag Value + 4,294,967,296 = Actual Stored Data Tag 155 D
Also you can find more Bradley Smoker manuals or manuals for other Computer Equipment.