3Com 3C389 manual Open Errors, Open Error Codes

Models: 3C389

1 86
Download 86 pages 47.35 Kb
Page 58
Image 58

Running the Diagnostics Program

5-11

Open Errors

Failure during the adapter open test might indicate that the PC Card is not properly configured to run on the network it is trying to open onto or that the PC Card is not properly configured for the system. The open test provides a return code and an open error code. If the return code is 07, then see “Open Error Codes” in this chapter for a more accurate description of the failure and suggested actions. If the return code is a value other than 00 or 07, record the error and contact your network administrator.

00Open completed successfully

01Incorrect command code

03PC Card open, should be closed

05Required parameters not provided

07Command cancelled, unrecoverable failure (see open error codes to isolate problem)

30Inadequate receive buffers

32Incorrect MAC address

33Incorrect PC Card receive buffer length

34Incorrect PC Card transmit buffer length

Open Error Codes

If the open test provides a return code of 07, there will be a corresponding error code. The open errors are returned in 2 bytes. The high-order byte is always 0 and the low-order byte contains the following information:

The phase of testing in which the error was encountered is in the high-order nibble (half-byte) of the low-order byte.

The error condition is in the low order nibble of the low-order byte.

Page 58
Image 58
3Com 3C389 manual Open Errors, Open Error Codes